Techniques in Gastrointestinal Endoscopy
Volume 9, Issue 4 , Pages 213-217, October 2007

Risks of Radiation Exposure in the Endoscopy Suite: Principles, Cautions, and Risks to Patients and Endoscopy Staff

  • E. Stephen Amis Jr, MD, FACR

      Affiliations

    • Corresponding Author InformationAddress reprint requests to E. Stephen Amis, Jr., MD, FACR, Department of Radiology, Montefiore Medical Center, 111 East 210th Street, Bronx, NY 10467.

Department of Radiology, The Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, NY.

Fluoroscopy, which uses x-rays to create an image, is a necessity in the endoscopy suite for various procedures, most commonly endoscopic retrograde cholangiopancreatography (ERCP). X-rays, high-energy electromagnetic waves, are considered a weak carcinogen, and beyond a threshold level of exposure (ie, 50 mSv) are believed to result in an increased risk of cancer. This risk applies to the patient, the endoscopist, and other staff in the suite. A thorough understanding of the physical principles underlying fluoroscopy is imperative so that radiation exposure to the patient and other personnel can be minimized. Of primary importance are the operating parameters of the fluoroscope (ie, voltage and current), the length of fluoroscopy beam-on time, and appropriate shielding. The concept of ALARA (As Low As Reasonably Achievable) should govern the use of fluoroscopy. Equivalent radiation doses to both patients and staff during ERCP have been reported. For patients, these compare favorably with doses from similar imaging exams which they may undergo. For endoscopists, the doses fall well below acceptable annual exposure limits.

Keywords: fluoroscopy, fluoroscopy technique, radiation exposure/dose, radiation protection

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 10.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1096-2883(07)00056-3

doi:10.1016/j.tgie.2007.08.016

Techniques in Gastrointestinal Endoscopy
Volume 9, Issue 4 , Pages 213-217, October 2007